Cutler-Hammer BR3040B200R Load Center, 40-Pole, 200 A, 30-Space, 40-Circuit, Main Breaker, NEMA 3R Enclosure
Promo Price:
Rainproof galvanized steel enclosure. Single phase, 3-wire, insulated/bonded neutral, 30 (1 in) spaces, 40 poles, 120/240 VAC. Main breaker type BW at 25,000 AIC. Furnished with hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 deg for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16 in x 34-1/8 in x 5-3/16 in. UL listed file E52977.
Voltage Rating | : | 120/240 V |
Current Rating | : | 200 A |
Number of Phases | : | 1 |
Number of Spaces | : | 30 |
Number of Poles | : | 40 |
Number of Circuits | : | 40 |
Breaker/Load Center Type | : | Main Breaker |
Interrupt Rating | : | 10 kA |
Cable Size | : | 2/0 AWG |
Bus Bar Material | : | Aluminum |
Enclosure Type | : | NEMA 3R |
Temperature Rating | : | 60 to 75 deg C |
Includes | : | Cover |